Background Contamination by Coplanar Polychlorinated Biphenyls (PCBs) in Trace Level High Resolution Gas Chromatography/High Resolution Mass Spectrometry (Hrgc/Hrms) Analytical Procedures

Notice - This site contains archived material(s)

Archive disclaimer
Archive disclaimer
Archived files are provided for reference purposes only. These files are no longer maintained by the Agency and may be outdated. For current EPA information, go to www.epa.gov. It is EPA's policy to support reasonable accommodation to persons with disabilities, pursuant to the Rehabilitation Act of 1973, 29 U.S.C. 791. If you need assistance with accessing archived files, contact EPA's Reasonable Accommodations or submit a request using the Contact Us form.


Abstract

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/ high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Impact/Purpose

journal articles

Citation

Ferrario, J., C. Byrne, AND A. Dupuy. Background Contamination by Coplanar Polychlorinated Biphenyls (PCBs) in Trace Level High Resolution Gas Chromatography/High Resolution Mass Spectrometry (Hrgc/Hrms) Analytical Procedures. CHEMOSPHERE. Elsevier Science Ltd, New York, NY, 34(11):2451-2465, (1997).

Additional Information

The full article is available in Downloads

This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.